Bed-head unit with integrated lighting · 1250 mm

Arnica

A wall-mounted bed-head unit for hospital wards and outpatient clinics that combines lighting with power, call-system and data connections, including 230 V sockets, data sockets, an equipotential socket and switches. It provides reflected general light for the room, local light for examination and reading, and a night light, with 3926 lm to 11413 lm of LED flux at 4000 K.

  • Combines lighting with power, call-system and data (ICT) connections
  • Two 230 V sockets and three switches, plus data and equipotential sockets
  • Reflected general light, local examination and reading light, and night light
  • Lens optics with opal PMMA or opal PMMA only; 3000 K or 4000 K with CRI above 80
  • IP40 and IK04; on/off driver; LED life L90/B10 at 102,000 hours

Provisional data — final values confirmed from test certificates.

3926–11413 lm
LED flux
21.7–64.8 W
Power
IP40
Protection rating
>80 CRI
Colour rendering
5
versions

Versions & light

Light figures are the LED flux the manufacturer publishes, at 4000 K. The light leaving the luminaire is lower and depends on the diffuser; ask us for photometric files.

VersionDimensionsLED fluxPowerColour temperatureDimming / control
Arnica 2600/13001250 × 130 × 110 mm3926 lm21.7 W3000 · 4000 KOn/off
Arnica 4400/22001250 × 130 × 110 mm6848 lm35.3 W3000 · 4000 KOn/off
Arnica 5200/13001250 × 130 × 110 mm6543 lm34.8 W3000 · 4000 KOn/off
Arnica 8000/20001250 × 130 × 110 mm11351 lm64.8 W3000 · 4000 KOn/off
Arnica 8800/22001250 × 130 × 110 mm11413 lm60.5 W3000 · 4000 KOn/off

All versions

Optics
Direct, asymmetric
Colour rendering
CRI >80
Light source
LED flux at 4000 K from the supplier datasheet; luminaire output is lower and depends on the diffuser. Each figure is the published total for the unit; the supplier does not say which light function each of the two nominal figures in the label refers to.

About colour rendering

Hygiene & construction

Hygiene

Mounting
Wall-mounted
Diffusers
Lens optics with opal PMMA · Opal PMMA
Lifetime
L90/B10 102,000 h

Lighting standards for healthcare

Construction

Material
Steel sheet body powder-coated white
Protection rating
IP40
Impact protection
IK04
Supply
220–240 V, 50–60 Hz
Operating temperature
5 °C to 30 °C (operating)
Body colour
White (RAL 9003)