- Home
- Healthcare lighting
- Arnica
Bed-head unit with integrated lighting · 1250 mm
Arnica
A wall-mounted bed-head unit for hospital wards and outpatient clinics that combines lighting with power, call-system and data connections, including 230 V sockets, data sockets, an equipotential socket and switches. It provides reflected general light for the room, local light for examination and reading, and a night light, with 3926 lm to 11413 lm of LED flux at 4000 K.
- Combines lighting with power, call-system and data (ICT) connections
- Two 230 V sockets and three switches, plus data and equipotential sockets
- Reflected general light, local examination and reading light, and night light
- Lens optics with opal PMMA or opal PMMA only; 3000 K or 4000 K with CRI above 80
- IP40 and IK04; on/off driver; LED life L90/B10 at 102,000 hours
Provisional data — final values confirmed from test certificates.
- 3926–11413 lm
- LED flux
- 21.7–64.8 W
- Power
- IP40
- Protection rating
- >80 CRI
- Colour rendering
- 5
- versions
Versions & light
Light figures are the LED flux the manufacturer publishes, at 4000 K. The light leaving the luminaire is lower and depends on the diffuser; ask us for photometric files.
| Version | Dimensions | LED flux | Power | Colour temperature | Dimming / control |
|---|---|---|---|---|---|
| Arnica 2600/1300 | 1250 × 130 × 110 mm | 3926 lm | 21.7 W | 3000 · 4000 K | On/off |
| Arnica 4400/2200 | 1250 × 130 × 110 mm | 6848 lm | 35.3 W | 3000 · 4000 K | On/off |
| Arnica 5200/1300 | 1250 × 130 × 110 mm | 6543 lm | 34.8 W | 3000 · 4000 K | On/off |
| Arnica 8000/2000 | 1250 × 130 × 110 mm | 11351 lm | 64.8 W | 3000 · 4000 K | On/off |
| Arnica 8800/2200 | 1250 × 130 × 110 mm | 11413 lm | 60.5 W | 3000 · 4000 K | On/off |
All versions
- Optics
- Direct, asymmetric
- Colour rendering
- CRI >80
- Light source
- LED flux at 4000 K from the supplier datasheet; luminaire output is lower and depends on the diffuser. Each figure is the published total for the unit; the supplier does not say which light function each of the two nominal figures in the label refers to.
Hygiene & construction
Hygiene
- Mounting
- Wall-mounted
- Diffusers
- Lens optics with opal PMMA · Opal PMMA
- Lifetime
- L90/B10 102,000 h
Construction
- Material
- Steel sheet body powder-coated white
- Protection rating
- IP40
- Impact protection
- IK04
- Supply
- 220–240 V, 50–60 Hz
- Operating temperature
- 5 °C to 30 °C (operating)
- Body colour
- White (RAL 9003)
Planning a clinical space?