Recessed patient-room luminaire · 595 × 595 mm

Salvia

A recessed patient-room luminaire for modular ceilings that gives three separate light distributions from one white steel housing: a main light for examination, an indirect light for rest and a louvred reading light. The main light gives up to 5199 lm of LED flux at 4000 K, and the indirect and reading lights add 2197 lm and 961 lm.

  • Three distributions in one unit: examination light, indirect rest light and reading light
  • Micro-prismatic and smooth opal PMMA diffusers, with a louvre for the reading light
  • Fits modular suspended ceilings; 595 × 595 × 130 mm
  • 3000 K or 4000 K with CRI above 80; on/off or DALI (DALI only on the 4000/2200 version)
  • LED life L80/B10 at 60,000 hours

Provisional data — final values confirmed from test certificates.

4550–5199 lm
LED flux
30.5–36.2 W
Power
IP20
Protection rating
>80 CRI
Colour rendering
2
versions

Versions & light

Light figures are the LED flux the manufacturer publishes, at 4000 K. The light leaving the luminaire is lower and depends on the diffuser; ask us for photometric files.

VersionDimensionsLED fluxPowerColour temperatureDimming / control
Salvia 5000/2200595 × 595 × 130 mm5199 lm36.2 W3000 · 4000 KOn/off · DALI
Salvia 4000/2200595 × 595 × 130 mm4550 lm30.5 W3000 · 4000 KDALI

All versions

Optics
Main direct light for examination · Indirect light for rest · Reading light through a louvre
Colour rendering
CRI >80
Light source
LED flux at 4000 K from the supplier datasheet; luminaire output is lower and depends on the diffuser. Figures are for the main (examination) light only; the indirect light adds 2197 lm at 13.5 W and the reading light 961 lm at 8.7 W.

About colour rendering

Hygiene & construction

Hygiene

Mounting
Modular suspended ceilings
Diffusers
Micro-prismatic PMMA with smooth opal PMMA · Louvre (reading light)
Lifetime
L80/B10 60,000 h

Lighting standards for healthcare

Construction

Material
Steel sheet body powder-coated white
Protection rating
IP20/40 (as published; room and ceiling sides not specified)
Impact protection
IK04
Supply
220–240 V, 50–60 Hz
Operating temperature
5 °C to 35 °C (operating)
Body colour
White (RAL 9003)

Planning a clinical space?

Send us the room layout, the room types or just a description. A lighting specialist replies within one working day.

Start a project

Or get the full range brochure (PDF)